Product Code : FMH-059
Product Description

Biology Laboratory Equipment  Manufacturer

Advanced Technocracy Inc. is Manufacturer, Exporter & Supplier of Biology Laboratory Equipment  Manufacturer

EXERCISES AND PRACTICAL POSSIBILITIES

Some Practical Possibilities of the Unit:

1.-  Load loss by friction in a rough pipe of 17 mm of interior diameter.

2.-  Load loss by friction in a rough pipe of 23 mm of interior diameter.

3.-  Load loss by friction in a smooth pipe of 6.5 mm of interior diameter.

4.-  Load loss by friction in a smooth pipe of 16.5 mm of interior diameter.

5.-  Load loss by friction in a smooth pipe of 26.5 mm of interior diameter.

6.-  Influence of the diameter in the load loss by friction in rough pipes.

7.-  Influence of the diameter in the load loss by friction in smooth pipes.

8.-  Load loss by friction in smooth and rough pipes.

9.-  Friction coefficient in a rough pipe of 17 mm of interior diameter.

10.-Friction coefficient in a rough pipe of 23 mm of interior diameter.

11.-Friction coefficient in a smooth pipe of 6.5 mm of interior diameter.

12.-Friction coefficient in a smooth pipe of 16.5 mm of interior diameter.

13.-Friction coefficient in a smooth pipe of 26.5 mm of interior diameter.

14.-Influence of the diameter in the friction coefficient in rough pipes.

15.-Influence of the diameter in the friction coefficient in smooth pipes.

16.-Friction coefficient in smooth and rough pipes.

17.-Load losses in the inclined seat valve.

18.-Load losses in the floodgate valve.

19.-Load losses in the filter.

20.-Load losses in the membrane valve.

21.-Load losses in an abrupt broadening.

22.-Load losses in the venturimeter

23.-Load losses in the diaphragm.

24.-Load losses in an abrupt contraction.

25.-Load losses in the accessories.

26.-Flow measurements by load loss in a venturimeter.

27.-Flow measurements by load loss in a diaphragm.

28.-Flow measurements by means of load loss.

29.-Load losses in a symmetrical bifurcation.

30.-Load losses after two 90Degree elbows.

31.-Load losses in a T-junction.

32.-Load losses for a 90Degree elbows.

33.-Load losses on the ball valve.

34.-Load losses for an elbow of 45Degree

35.-Load losses in a inclined T-junction.

36.-Study of laminar regime.

37.-Study of turbulent regime.