Product Details:

  • Power 440 V. A.C., 50 Hz. Volt (v)
  • Voltage 230 V AC Volt (v)
  • Application Lab Equipment
  • Click to view more
X

Price And Quantity

Product Specifications

  • Lab Equipment
  • 440 V. A.C., 50 Hz. Volt (v)
  • 230 V AC Volt (v)

Product Description

Range Of Experiments

  • To observe the working principal of heat pump cycle
  • To determine Actual cooling C.O.P, Carnot C.O.P., Theoretical C.O.P
  • Actual heating C.O.P., Relative C.O.P., Ton of Refrigeration Etc
  • To determine the efficiency of the heat pump system
  • Observe the working of refrigeration cycle also.

 

Experimental Set up:

  • Compressor:  Tone, Hermetically sealed compressor,
  • Condenser : Coiled Tube Heat Exchanger acts as a condenser. Copper coil is merged in water tank to cool down the gas temp.Continuous water flow circulation is required to extract the heat of gases.
  • Expansion device: Thermostatic expansion valve.
  • Evaporator coil: Coiled Tube Heat Exchanger copper coil is merged in water tank to extract the heat from water tank. Same can be mentioned by electric heater.
  • Electric Heater: For Balancing refrigerating effect produced.
  • Rotameter: For measuring liquid flow of Refrigerant.
  • Energy Meter: One each for power measurement of compressor & heater.
  • Pressure Gauge: 2 Nos. for H.P., L.P.measurement
  • HP/LP cut out: 1 No. to suit compressor,
  • Service valve needle type: 1 No.
  • Thermostat: 1 No.

 

Control Panel :

  • 12 Channel Digital Temperature Indicator
  • Dimmerstat : 230 V. AC single phase for heating control
  • Main On/Off Switch
  • Voltmeter: 0 - 250 V.