Wet Cooling Tower

Wet Cooling Tower

Product Details:

X

Product Description

Advanced Technocracy Inc. is Manufacturer, Exporter & Supplier of  Wet-Cooling-Tower

Learning Objectives / Experiments

  • Thermodynamic principles of the wet cooling tower
  • Changes of state of the air in the h-x diagram
  • Determination of the cooling capacity
  • Energy balances
  • Calculation of process parameters, such as maximum cooling distance, cooling zone width etc. in conjunction with the cooling columns WL 320.01-WL 320.04
  • Comparison of different wet deck surfaces

Specification

  • Principle of a wet cooling tower with cooling column and forced ventilation
  • Interchangeable cooling columns with different wet deck surfaces available as accessories
  • Water circuit with pump, filter, valve and a nozzle as atomiser
  • Three-stage heater with thermostat for water heating
  • Radial fan for forced ventilation
  • Throttle valve to adjust the air flow
  • Demister unit at the outlet of the cooling columns minimises water loss
  • Tank for additional water compensates for water loss
  • Display of temperature, differential pressure, flow rate and humidity

Technical Data

Cooling column

- specific surface of the wet deck surface: 110m²/m³

- cross-section: 150x150mm

Volumetric air flow measurement via orifice: D=80mm

Heater, adjustable in three stages: 500-1000-1500W

Thermostat: switches off at 50°C

Fan

  • power consumption: 250W
  • max. differential pressure: 430Pa
  • max. flow rate: 13m³/min

Pump

  • max. head: 70m
  • max. flow rate: 100L/h

Tank for additional water: 4,2L 

Measuring ranges

  • differential pressure (air): 0...1000Pa
  • flow rate (water): 12...360L/h
  • temperature: 2x 0...50°C, 3x 0...100°C
  • humidity: 10...100% r.h. 